FireLite® |
 |
Now with ultraHDTM Technology for improved surface quality, clarity and color |
 |
Fire-rated up to
90 minutes w/
required hose stream
test |
 |
Listed for use in non-safety fire-rated applications |
 |
Clear, wireless
glass ceramic |
 |
Passes positive
pressure test
standards UL
10C, UBC 7-2 and
UBC 7-4
|
 |
May be lightly
sandblasted or
etched on one
side without
affecting fire
rating |
|
Note:
This product is
not a barrier to
radiant heat.
This product
does not meet
test standards
ASTM E-119 or UL
263. If your
jurisdiction
requires a
"barrier to
heat" product,
please see
Pyrostop by TGP.
|
|
FireLite® NT |
 |
Now with ultraHDTM Technology for improved surface quality, clarity and color |
 |
Fire-rated up to
90 minutes
(3-hours in
doors) w/ required hose
stream test.
|
 |
Impact safety-rated - meets ANSI Z97.1 and CPSC 16CFR1201 (Cat. I and II) |
 |
Glass ceramic with high performance surface-applied fire-rated film |
 |
Clear, wireless
glass ceramic |
 |
Withstands
thermal shock |
 |
Passes positive
pressure test
standards UL
10C, UBC 7-2 and
UBC 7-4
|
 |
May be lightly
sandblasted or
etched on one
side without
affecting fire
rating
|
|
Note:
This product is
not a barrier to
radiant heat.
This product
does not meet
test standards
ASTM E-119 or UL
263. If your
jurisdiction
requires a
"barrier to
heat" product,
please see
Pyrostop by TGP.
|
|
FireLite® Plus |
 |
Now with ultraHDTM Technology for improved surface quality, clarity and color |
 |
Fire-rated up to
90 minutes
(3-hours in
doors) w/ required hose
stream test.
|
 |
Impact
safety-rated --
meets ANSI Z97.1
and CPSC 16
CFR1201 (Cat. I
and II) |
 |
Clear, wireless
glass ceramic |
 |
Withstands
thermal shock |
 |
Passes positive
pressure test
standards UL
10C, UBC 7-2 and
UBC 7-4
|
 |
May be lightly
sandblasted or
etched on one
side without
affecting fire
rating |
|
Note:
This product is
not a barrier to
radiant heat.
This product
does not meet
test standards
ASTM E-119 or UL
263. If your
jurisdiction
requires a
"barrier to
heat" product,
please see
Pyrostop by TGP.
|
| WireLite® |
 |
Fire-rated up to
45 minutes
w/ required hose
stream test. |
 |
Listed for use in non-safety fire-rated applications |
 |
Available in Diamond Clear (3/4" pattern) and Georgian Clear (1/2" pattern) |
 |
Withstands
thermal shock |
 |
Passes positive
pressure test
standards UL
10C, UBC 7-2 and
UBC 7-4 |
 |
May be lightly
sandblasted or
etched on one
side without
affecting fire
rating |
Note: This product is
not a barrier to
radiant heat.
This product
does not meet
test standards
ASTM E-119 or UL
263. If your
jurisdiction
requires a
"barrier to
heat" product,
please see Pyrostop by TGP.
|
| WireLite® NT |
 |
Fire-rated up to
90 minutes
w/ required hose
stream test. |
 |
Impact safety-rated - meets ANSI Z97.1 and CPSC 16CFR1201 (Cat. I and II) |
 |
Wired glass with high performance surface-applied fire-rated film |
 |
Available in Diamond Clear (3/4" pattern) and Georgian Clear (1/2" pattern) |
 |
Withstands
thermal shock |
 |
Passes positive
pressure test
standards UL
10C, UBC 7-2 and
UBC 7-4 |
 |
May be lightly
sandblasted or
etched on one
side without
affecting fire
rating |
Note: This product is
not a barrier to
radiant heat.
This product
does not meet
test standards
ASTM E-119 or UL
263. If your
jurisdiction
requires a
"barrier to
heat" product,
please see Pyrostop by TGP.
|
| |